Statistical Design of Experiments
Statistical Design of Experiments
Exercise 2
Exercise 2
1/16 Fractional Factorial (L
1/16 Fractional Factorial (L
8
8
)
)
Fuel Pump      Fuel                                            
Response       
Test   
Input Air   Fuel Pump TDC Set
Mfg
Nut     Pump Gear  Backlash                            Fuel Pump             
#        
Press.      Mfg
Nut       Point       Torque Set   Torque         Tool
Assoc.             Timing (mm)
1            100
psi
snug
.75
deg
top first      
two step
METC
Bob
1.21     1.17     1.26        
2            100
psi
snug
.75
deg
bottom first
one step
spring
Jim
1.11     1.15     1.14            
3            100
psi
loose
TDC       top first      
two step
spring
Jim
1.22     1.32     1.29       
4
100
psi
loose
TDC       bottom first   one step
METC
Bob
1.35     1.38     1.36      
5
80
psi
snug
TDC        top first        one step
METC
Jim
1.25     1.23     1.26        
6
80
psi
snug
TDC       bottom first   two step
spring
Bob
1.20     1.16     1.26        
7
80
psi
loose
.75
deg
top first        one step
spring
Bob
1.19     1.12     1.18        
8
80
psi
loose
.75
deg
bottom first  two step
METC
Jim
1.18     1.23     1.27